NEW from Fidia Pharma USA Inc.
Quality, consistency, and reliability—all in one cost-effective platelet rich plasma (PRP) system.
Rx Only
INDICATIONS FOR USE: The RICHPLAT ORTHO™ Platelet Rich Plasma System is designed to be used for the safe and rapid preparation of autologous platelet rich plasma (PRP) from a small sample of peripheral blood at the patient’s point of care. The PRP is mixed with autograft and/or allograft bone prior to application to a bony defect for improving handling characteristics.
Why RICHPLAT ORTHO™ PRP? It delivers everything you’ve been looking for in a PRP system:
QUALITY, CONSISTENT PRP
Closed-system kit design1 delivers safe, consistent, high-quality PRP
SIMPLE, COMPACT CENTRIFUGE
One-touch centrifugation minimizes variability and risk of error; requires just 1.35 square feet of counter space
LOW BLOOD DRAW
Patients will appreciate the 18mL blood draw volume,2,a which produces 8mL of concentrated PRP at 2.3x final concentration above baseline2,b
RAPID TURNAROUND
8-minute centrifuge spin to process PRP
COST EFFECTIVENESS
Competitively priced kits and durable, maintenance-free centrifuge help you maximize your investment
A NAME YOU CAN TRUST
Brought to you by Fidia, a leader in hyaluronic acid technology
RICHPLAT ORTHO™ PRP Kit
Closed-system Kit: Mechanically prevents the transfer of environmental pollutants to the product and/or device, as well as the accidental exit of the PRP. This minimizes the risk of any type of contamination of the PRP and ensures the quality of the product1
Low blood draw volume: 18mL of whole blood collected2,a
Final concentrated PRP volume: 8mL
2.3x final platelet concentration above baseline2,b
99% reduction in red blood cells in the final concentrated PRP collection2,b
Blood Collection Set
The following accessories are required to produce PRP using the RICHPLAT ORTHO™ Platelet Rich Plasma System (supplied separately):
- 2mL Anticoagulant Citrate Dextrose Solution A, (ACD-A)
- 1mL 10% Calcium Chloride (CaCl2 10%) solution (for bone graft handling)
- A general-purpose centrifuge
Please refer to the RICHPLAT ORTHO™ PRP System Instructions For Use.
a 20mL of anticoagulated whole blood (18mL whole blood + 2mL ACD-A).
b Testing was conducted immediately (Time=0hr) after the preparation of the concentrated PRP.
Concentrating Kit / Counterbalance Tube
BOOST 2 Flex Ultra Compact PRP Centrifuge
The smallest centrifuge specifically designed for PRP preparation: Requires just 1.35 square feet of counter space3
Pre-programmed for one-touch spin—minimizes risk of error in centrifugation
Locks to just one setting, making technicians’ work easy, safe, and simple
Easy to monitor: Process samples more efficiently with LED lid lighting3
Shows RPM and remaining spin time on the digital display
Rapid 8-minute centrifuge spin time2
Safe and durable, with brushless, CoolFlow system maintaining sample temperature, imbalance protection, and heavy-duty guard bowl with shatterproof lid, which can only be opened when the centrifuge’s rotor is stopped3
Ready-to-run horizontal rotor, 2 tube holders, buckets, and a 2-year warranty included3
Simple and intuitive setup in your office
Complete instructions for use, operations guide, and safety tips with troubleshooting to keep your system running day after day, procedure after procedure
Designed, built, and supported in the USA by Drucker Diagnostics, for years of worry-free operation
- BOOST 2 Flex Specifications
- Speed/G-Force
2000 RPM, 600g - Dimensions (W x D x H)
13 x 15 x 9 in (33 x 38 x 23 cm) - Weight (lbs.)
14 - Power
95 to 253 V – 50/60 Hz - Resting Tube Angle
30° - Tube Spin Angle
90° horizontal
System Instructions for Use Video
Get useful information and support for the RICHPLAT ORTHO™ PRP System, including instructions for use, helpful tips, and troubleshooting resources.
For information or ordering the RICHPLAT ORTHO™ PRP System, please contact your Fidia Representative or Fidia Customer Service.
- customerservice@fidiapharma.us
- (844) 307-7223
For Boost 2 Flex Centrifuge Service & Support
- support@DruckerDiagnostics.com
- (814) 692-7661, (866) 265-1486 (US Toll Free)